Invasive (IV) and non-invasive (NIV) mechanic ventilation with different advanced ventilation modes for adult and pediatric service
State-of-the-art, light, portable and robust technology. 10.4″ touch screen with 3 simultaneous curves on the screen (volume, current, flow, and pressure) and advanced technical and physiological alarm system.
Learn about Ruah Lung Ventilator and take this safety to your patients.
Ruah Lung Ventilator relies on visual and sound alarms that are easy to understand, that can be set as low, medium or high priority. Apnea Alarms; Low FiO2; High or Low PEEP; Critical battery (below 20%) and respiratory circuit disconnection. Besides INDIVIDUAL alarms for High or Low inspiratory pressure, minute volume, current volume, and respiratory frequency.
Health Ministry Registration | 80058130025 |
PARAMETERS AND CONTROL | |
Current Volume | 10 a 2 .2 00ml |
Inspiratory Pressure | até 80cmH2O |
Support Pressure | até 60 cmH2O |
PEEP | 0 a 50 cmH2O |
Respiratory Flow | 1 a 100 l/min |
Respiratory Frequency | 1 a 99 rpm |
Inspiratory Time | 0,1 a 30s |
Sensibility by pressure trigger | -9.9a-0.1 cmH2O |
Sensibility by flow pressure | 1 a 10 l/min |
O2 inspiration fraction | 21 a 100 % |
I:E ratio | de 1:99 e invertida de 3:1 |
Minute Volume | 1 a 100 l/min |
Tidal Volume | 10 a 2200 ml |
Inspired pressure on PEEP | 1 a 80 cmH2O |
Pressure Support on PEEP | 1 a 60 cmH2O |
Apnea Time | 0 a 60s |
Airway Pressure: Peak | 1 a 80 cm H2O |
Inspiratory Time | 0.1 a 11.25s |
Battery Charge Level | 0 a 100% |
USB connector | Software update access |
Backup Ventilation | Available in all ventilation modes |
Freeze Graphs Function | via touchscreen and with grids that facilitate interpretation |
Standby | quick access button that stops ventilation and keeps the fan on standby without changing the schedule |
Flow Waveforms | Square, ascending (or accelerated) and decelerated (or descending) |
OXYGEN INPUT | 30 A 75 PSIG |
COMPRESSED AIR INLET | 30 A 75 PSIG |
AC input | 100 ~ 240 V 50-60 Hz and Current consumption: 1.25 A MAX |
FiO2 response time from 21% to 90% | Up to 15 seconds |
Accuracy of the Internal Oxygen Mixer | +- 8% |
Connector Type of Internal Oxygen Mixer | DISS |
Oxygen receiver pressure | 40-70 psig / 275-480 kPa |
Display | 10.4’’ touch screen |
Degree of impermeability | Degree of impermeability |
EMC | Class B |
Product dimensions | 310 mm (L) x 280 mm (C) x 350 mm (A) |
Operation mode | Continuous |
Inspiratory and Expiratory pause time | de 1 s até 60s |
O2 time 100% | 1 a 60 min |
Loops | volume/pressure, flow/volume |
Atende pacientes de | 5 a 250kg |